HP ProLiant servers and blades are a mainstay in the data center. The market leader for some years with good reason, ProLiant technology represents a remarkably stable continuum of server hardware management tools. HP SmartStart CDs and DVDs have been used countless times since Compaq ProLiant days to accelerate and standardize server deployments by integrating the right HP drivers and utilities into the OS installation process.
![]()
It is important to update the firmware (Also called - flashing the ROM) as part of regular server maintenance. In addition, checking for specific firmware updates in between regular updates helps to keep the server performing optimally. Access HP Proliant DL385 BIOS [closed] Ask Question. Up vote 0 down vote favorite. Non-ECC memory on Proliant DL385 g5. HP ProLiant DL360 G7 hangs at “Power and Thermal Calibration” screen. HP ProLiant ML350 G6 powerup issue. HP ProLiant Gen8 BIOS settings for VMware ESXi. Download the latest drivers for your HP ProLiant DL320 G5 to keep your Computer up-to-date. Firmware Upgrade for HP ProLiant DL380 G4 Servers version 4.02 I've been searching for the Firmware upgrade for a DL380 G4. I am looking. Examples: 'LaserJet Pro P1102 paper jam', 'EliteBook 840 G3 bios update' Search help. Permainan extreme balpan mobil hp asha. Tips for better search results. Ensure correct spelling and spacing - Examples: 'paper jam'. Important Print Security Update. HP was recently made aware of a vulnerability in certain inkjet printers by a third-party researcher. HP has updates available for.
No SmartStart for HP Gen8 ProLiant, Windows Server 2012
A hardware migration to the Gen8 ProLiant platform prompted HP to end the SmartStart legacy with version 8.70b (12/2011) being the last media version. HP stated that SmartStart will not be updated beyond version 8.70. SmartStart will still be available on the web for supported ProLiant G7 and earlier servers through their supported end of life. Since Windows Server 2012 was not an operating system choice in SmartStart 8.70, it won't be possible to use SmartStart to install Windows Server 2012.
![]()
New Gen8 and later ProLiant servers use a different technique for assisted installation. There is no media kit included with ProLiant Gen8 products. Intelligent Provisioning replaces SmartStart CDs for ProLiant Gen8 servers. The software that came on SmartStart media is now embedded on a flash chip on ProLiant Gen8 servers and Gen8 server blades. The pre-loaded flash chip is bootable when a user presses the F10 key during server boot (POST). The server will then boot to the pre-loaded flash chip and show the Intelligent Provisioning software.
New way to provision HP ProLiant: Smart Update Manager (HP-SUM)
For everyone that does not have ProLiant Gen8 servers, use the Service Pack for ProLiant (SPP) at http://www.hp.com/go/spp to get firmware and software updates, since only Gen8 can use Intelligent Provisioning. You will also need to use the SPP if you are installing Windows Server 2012 on any HP hardware prior to Gen8. There is also a Windows Server 2012 Supplement for Service Pack for ProLiant that includes drivers and software for all ProLiant servers.
A common scenario is that you will install Windows Server 2012 on a pre-Gen8 ProLiant manually, that is, without HP software-assisted installation. Then afterwards you will run the SPP and/or Windows Server 2012 Supplement to install the HP hardware integration features. HP published a 13-page Technical white paper in September 2012 on Windows Server 2012 implementation recommendations, which makes clear that HP supports Windows Server 2012 installation on G7 and Gen8 ProLiant hardware, and also advises which drivers to use and where they are located (SPP or Supplement). Not all ProLiant hardware previous to G7 and Gen8 may be supported by HP drivers and software on Windows Server 2012.
Figure A shows the HP Smart Update Manager (HP-SUM) interface running on a freshly installed Windows Server 2012 computer, an older ProLiant G5. HP-SUM will detect the latest editions of the appropriate software and drivers and show whether they are available on the DVD, to download, or in a local repository. This older G5 ended having no driver support for the HP management module, but all other drivers and software installed and worked as expected.
Figure AHP Smart Update Manager (SUM) locates the latest versions of Windows Server 2012 drivers. (Click to enlarge)To run HP-SUM, download the SPP software at hp.com; the current release at this writing is 2012.08. Expand the software distribution, locate and run the E:hpswpackageshpsum.exe file (where E: represents the drive letter the virtual SPP software DVD is mounted to). If you will be installing HP Agents, it is recommended that you pre-install the SNMP Service feature on Windows Server 2012. The HP Systems Insight Homepage on the computer will require SNMP to render any data.The first thing HP-SUM will do is prompt you to connect over the Internet to ftp.hp.com for the latest updates. If you have established an on-site HP software repository, you can connect to that rather than, or in addition to, using the Internet. Figure B shows the download of components from HP.com in progress. The component download and the software install are two independent steps, and there is an ability to add other ProLiant to a list of servers to be updated. This allows you to download the software on one ProLiant and install it on multiple other ProLiants at the same time.Figure BHP Smart Update Manager (SUM) downloading updated drivers from HP.Install and configure with HP ToolsYou will need to push the Enter Credentials button to specify a username/password—or to use the currently logged on user—for the install work. After doing a self-discovery on the local server and a discovery of any other network servers you have added to the list, HP-SUM will display any failed dependencies needed to fix to install the updates. A 'Select bundles' option makes it easy to see all the software available and selected for installation. After installation and reboots, the handy HP tools like HP Array Configuration Utility (ACU) and Integrated Lights Out (ILO) configuration tool are ready to use. Access HP tools from the Windows Start screen shown in Figure C.Hp Dl320 G5 Firmware Update
Posted by3 years ago
Archived
So I just recently got my hands on a cheap HP DL360 G6, and have already started investigating some cheap hardware upgrades for the thing. It's the perfect balance of old enough that additional hardware is relatively cheap to come by, but recent enough to not be terrible in terms of performance, virtualisation support and not dimming the lights in the neighbourhood when powering the thing on. It's currently on its way, and hopefully should arrive by this Friday or Monday. Driver hp laserjet d1360.
I have grand plans for the thing, involving a CPU upgrade, memory upgrades and possibly installing an additional SAS backplane for more storage, but before doing anything crazy, I figured the best thing to do would be to get all the necessary firmware up to date, including the server's BIOS. Hp laserjet 6p driver download windows 7 64.
Hp Dl580 G5 Bios Update
..and that's the part where I learnt that in 2014, HP decided to specifically put server firmware behind a paywall, requiring a support contract with HP to gain access to BIOS downloads.
Proliant Dl580 G5 Firmware Update
So this is where I need your help. I'd like to download the latest server BIOS for the ProLiant DL360 G6. As far as I can tell, only this and the HP Service Pack is behind the paywall, and all other drivers and stuff are publicly accessible. Crack 10. I either need a kind soul to download the BIOS for me, or offer some advice on how to get around HP's paywall without forking out money for a support contract for a retired server I bought for peanuts off of eBay.
Hp Proliant Dl320 G5p Bios Update
Can anyone out there with access to HP support give me a hand?
62 comments
Comments are closed.
|
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |